Our devices for environmental analysis
Single-beam photometer Beckmann DU640
Single-beam photometer for determining the optical density of suspensions, as well as protein measurement, TS determination and o-PO4.
Dual-beam photometer Shimadzu UV2450
Photometer for the determination of typical wastewater components such as NH4+, NO2-, NO3-, o-PO43-, or Fe2+/Fe3+ and others.
HPLC System 1 Jasco PU-980 with UV-975 detector
The Jasco LC system is suitable for the qualitative and quantitative analysis of dissolved organic substances.
HPLC System 2 Dionex LC system with PDA
The Dionex LC system is suitable for the qualitative and quantitative analysis of dissolved organic substances.
Gas chromatograph 1 Shimadzu GC-2014 with FID & ECD
The GC-2014 is used for the qualitative and quantitative determination of trace gases such as CHCs, CFCs and SF6.
Gas chromatograph 3 Shimdazu GC 2014
The GC-2014 is used for the qualitative and quantitative determination of permanent gases.
Gas chromatograph 2 Shimadzu GC-14A with FID
The GC-14A is used for the qualitative and quantitative determination of MKWs.
Ion chromatography Dionex DX-120 IC
The IC is used to determine various anions such as Cl-, F-, Br-, SO43-, PO43- and others.
Microwave pressure digestion MARS 5 from CEM
The MARS 5 is used for the digestion of liquid and solid samples from waste water, waste, various environmental samples as well as oily phases, dyes and other formulations.
Sample evaporation station Horizon technology XcelVap
The XcelVap is used for fast and precise partial or complete evaporation of various liquid phases in the nitrogen stream. The XcelVap is primarily used for interference-free sample enrichment.
Sample fraction collector Pharmacia Fraction Collector FRAC-100
The automated sample collector can collect up to 175 samples depending on volume or time.
Sample preparation SPE IST VacMaster
The SPE station from VacMaster is used to enrich dissolved samples in solid phases.
Respirometer Kirsch BOSCH refrigeration machine Respirometer
The respirometer is primarily used to determine the ready biodegradability of organic substances according to OECD test method 301-F.
Total carbon analyzer DIMATEC DIMATOC-2000
The TOC analyzer is used for the quantitative determination of total carbon (TC) and inorganic carbon (TIC). Organic carbon is determined by measuring the difference between TC and TIC.
Disk reader Labsystems Fluoroskan II
The fluorescence plate reader can be used for screening and high sample throughput. It is primarily used for toxicity tests and for determining nucleic acids and protein concentrations
Contact angle measuring device datphysics Contact Angle System OCA
The contact angle measuring device is used to characterize the surface of microorganisms and various other surfaces. The device can be used to determine the static and dynamic contact angle.
Dry weigher KERN DAB
The dry weigher is primarily used to determine the dry substance of wastewater sludge.
Thermal oven NEY VULCAN 3-550
The thermal furnace is primarily used to determine the loss on ignition of wastewater sludge.